Make: Proceq
Model: (UPV) PL-200PE
- Determining the uniformity of concrete in structures like bridges and buildings
- Determining the depth of cracks using Pulse Echo technology.
- Identifying internal cavities, cracks, voids, and honeycombing within the material.
- Investigating the overall structural integrity of building materials like concrete, ceramics and rock.
- Evaluating the relative compressive strength of concrete based on its sonic properties
- To check the uniformity/ quality of concrete/ concrete structures
- To identify internal cavities, cracks, voids, and honeycombing within the concrete material/ concrete structures
Room No.:201 Souvenir building - 2nd floor
NDT LAB, School of Civil Engineering
Vellore Institute of Technology (VIT), Vellore.
Dr. A. Abdul Rahim,
Professor
Department of Structural and Geotechnical Engineering,
Vellore Institute of Technology (VIT), Vellore - 632 014, Tamil Nadu, India
Email: abdulrahim.a@vit.ac.in || Mobile: +91 7200711542
Instrument email ID: sce.upvt@vit.ac.in
Chares arrived based on the visual inspection and condition of the structures.
S. No.
|
Experiment Details
|
UG /PG Students from Academic Institutions
(in INR)
|
Research Scholar from Academic Institution
(in INR)
|
Project Staff
from Academic Institution
(in INR)
|
Faculty Members
from Academic
Institutions (in INR)
|
Research Scientist
from R&D Organizations
(in INR)
|
Industry Personnel from Industry
(in INR)
|
1
|
Ultrasonic Pulse Velocity Tester
|
300/m2
|
300/m2
|
300/m2
|
300/m2
|
400/m2
|
400/m2
|
* Charges for per sample in INR (+ applicable GST)