CO2 Research and Green Technologies Centre

Home Facilities CO2

Make: Agilent

Model: 5977B GC-MS

  • Analysis of gaseous compounds like CO2, CO, CH4, etc.
  • Analysis of Pesticides in Food Stuffs
  • Analysis of Petrochemical and Hydrocarbon related compounds

Useful for multiple disciplines of research such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing.

Room no.: NA
Ground floor
CO2 Research & Green technologies Centre

Dr. J. Ranjitha & Dr. S. Vijayalakshmi
Assistant Professors
CO2 Research & Green Technologies Centre
VIT, Vellore, 632014.
Email:co2.agccms@vit.ac.in Phone: 0416 2202505

Make: Jasco

Model: 4600

  • Analysis of Solids, liquids, and gasses
  • Identification of components of an unknown mixture
  • Identification of inorganic and organic compounds

Useful for multiple disciplines of research such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing.

Room No.: NA
Ground floor
CO2 Research & Green technologies Centre

Dr. J. Ranjitha & Dr. S. Vijayalakshmi
Assistant Professors
CO2 Research & Green Technologies Centre
VIT, Vellore, 632014.
Email:co2.ftir@vit.ac.in

Make: Geonica

Model: Suntracker 2000

Data available from 2015 to till date

Researchers working in Solar Energy PV forecasting, Building, Cold storage, Agriculture, Wind Energy.

Room No: Open Terrace
Second floor
CO2 Research & Green technologies Centre

Dr. G. Praveenkumar
Assistant Professor (Sr.)
CO2 Research & Green Technologies Centre
VIT, Vellore, TN-632014.
Email: co2.weastat@vit.ac.in
Phone: 0416 2202506

Make: Systronics

Model: 119

Wavelength
  • Range of 200 to 1100 nm
  • Accuracy of +/- 1 nm
  • Repeatability: +/- 0.5
  • Bandwidth of 2.0
Photometric
  • Range of -0.3 to 2.5 Abs 0-100% T
  • Accuracy of +/- 0.005 Abs at 1 Abs
  • Repeatability: +/- 0.002 Abs at 1 Abs
  • Stray light less than 0.1% at 220nm & 370nm

Useful for multiple research disciplines such as environmental, chemical, petrochemical, food, forensic, pharmaceutical, and material testing.

Room No.: NA
First floor
CO2 Research & Green technologies Centre

Dr. J. Ranjitha & Dr. S. Vijayalakshmi
Assistant Professors
CO2 Research & Green Technologies Centre
VIT, Vellore, 632014.
Email:co2.pc@vit.ac.in
Phone: 0416 2202505

Make: Hitachi

Model: UH5300

Range 0 to 1000 NTU

Used to measure the haziness or cloudiness in a liquid medium such as water, solutions, beverages like wine, beer, and soft drinks, and solid medium like window glass or translucent glass

Room No.: NA
First floor
CO2 Research & Green technologies Centre

Dr. G. Velvizhi
Associate Professor
CO2 Research & Green Technologies Centre
VIT, Vellore, TN-632014.
Email: co2.uv@vit.ac.in
Phone: 0416 220 2503

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 200
Research Scholar from Academic Institution 200
Project Staff from Academic Institution 200
Faculty Members from Academic Institution 200
Research Scientist from R&D Organizations 200
Industry Personnel from Industry 300
Personnel from Non - Government Organization 200

Make: Lovibond

Model: RD 125

Range: 0 to 1000 mg/l

Used to measure organic pollutant in water and waste water Useful for multiple disciplines of research such as physics, chemistry, material science, metallurgy, biology, nanotechnology and nano-science

Room No: Open Terrace
Second floor
CO2 Research & Green technologies Centre

Dr. G. Velvizhi
Associate Professor
CO2 Research & Green Technologies Centre
VIT, Vellore, TN-632014.
Email: co2.cod@vit.ac.in
Phone: 0416 220 2503

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 350
Research Scholar from Academic Institution 350
Project Staff from Academic Institution 350
Faculty Members from Academic Institution 350
Research Scientist from R&D Organizations 350
Industry Personnel from Industry 400
Personnel from Non - Government Organization 350

Make: Systronics

Model: 132

Range 0 to 1000 NTU

Used to measure the haziness or cloudiness in a liquid medium such as water, solutions, beverages like wine, beer, and soft drinks, and solid medium like window glass or translucent glass

Room No.: NA
First floor
CO2 Research & Green technologies Centre

Dr. G. Velvizhi
Associate Professor
CO2 Research & Green Technologies Centre
VIT, Vellore, TN-632014.
Email: co2.cod@vit.ac.in
Phone: 0416 220 2503

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 150
Research Scholar from Academic Institution 150
Project Staff from Academic Institution 150
Faculty Members from Academic Institution 150
Research Scientist from R&D Organizations 150
Industry Personnel from Industry 200
Personnel from Non - Government Organization 150