Centre for Nanotechnology Research

Home Facilities CNR

Make: Nanosurf, Switzerland

Model: Nanosurf AFM

  • AFM-Contact mode
  • To study the morphology, roughness and thickness of the coated sample at nm to um level.
  • 3D imaging

The Nanosurf AFM is an easy-to-use instrument that can make nanometer scale resolution measurements of topography and roughness of a sample surface, in contact mode. The Nanosurf AFM is easier to use and takes less time to learn. No alignment or adjustment of the laser is needed, as special tips with an in built alignment system is used. The Nanosurf AFM is ideal to check surface structures, defects.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob,
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.afm@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 1000
Research Scholar from Academic Institution 1000
Project Staff from Academic Institution 1000
Faculty Members from Academic Institution 1000
Research Scientist from R&D Organizations 2000
Industry Personnel from Industry 2000
Personnel from Non - Government Organization 2000

Make: Nano Tec, India

Model: N/A

Fabricate a sol gel based thin film.

Dip coater is used for thin film applications. Substrates will be slowly dipped and automatically retracted to form thin film. Dipping speed can be varied from 1 mms-1. Number of dip coating can also be programmed. The retraction of substrate after is at automated speed. The substrate can be dried up to 100'C using heating unit coupled with dip coater.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob,
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.dc@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 100
Research Scholar from Academic Institution 100
Project Staff from Academic Institution 100
Faculty Members from Academic Institution 100
Research Scientist from R&D Organizations 200
Industry Personnel from Industry 200
Personnel from Non - Government Organization 200

Make: PECO Chennai

Model: E Spin Nano

Electrospinning of nanofiber.

Fabrication of nanofiber sheets for filters, packaging and biomedical applications.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob,
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.ea@vit.ac.in
Phone: 0416-2202412

Make: Olympus

Model: Olympus BX61

Study the morphological features of transparent and opaque sample.

To determine the size, lateral dimension (xy) and height (z) information of the sample.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob,
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.om@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 200
Research Scholar from Academic Institution 200
Project Staff from Academic Institution 200
Faculty Members from Academic Institution 200
Research Scientist from R&D Organizations 400
Industry Personnel from Industry 400
Personnel from Non - Government Organization 400

Make: Anton Paar

Model: Litesizer 500

  • Particle characterization from the nano- to the micrometer range
  • Particle size measurements via dynamic light scattering at three different measurement angles
  • Determination of zeta potential using patented cmPALS
  • Molecular mass and refractive index measurement

The Litesizer 500 is an instrument for characterizing nano- and microparticles in dispersions and solutions. It determines particle size, zeta potential, and molecular mass by measuring dynamic light scattering (DLS), electrophoretic light scattering (ELS), and static light scattering (SLS).

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.psa@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 500
Research Scholar from Academic Institution 500
Project Staff from Academic Institution 500
Faculty Members from Academic Institution 500
Research Scientist from R&D Organizations 1000
Industry Personnel from Industry 1000
Personnel from Non - Government Organization 1000

Make: Horiba France

Model: XploRA PLUS

  • 10x faster Raman imaging
  • Improved detection and sensitivity
  • Full Confocality for complete image detail
  • Full optical microscope so you can see your samples
  • Maximum detail, resolution and range for enhanced spectroscopy

Raman Spectroscopy is a non-destructive chemical analysis technique which provides detailed information about chemical structure, phase and polymorphy, crystallinity and molecular interactions. It is based upon the interaction of light with the chemical bonds within a material. The Green laser light of 532 nm used for the analysis. It consists of three eye pieces with three different magnifications (10X, 50X and 100X). The Height of eye piece can be varied to do mapping analysis. Real time Display (RTD) is used to analysis the insitu reaction of the sample. The Thickness of the coated surface can be analysed using this instrument.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.rs@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 500
Research Scholar from Academic Institution 500
Project Staff from Academic Institution 500
Faculty Members from Academic Institution 500
Research Scientist from R&D Organizations 1000
Industry Personnel from Industry 1000
Personnel from Non - Government Organization 1000

Make: Holmarc opto-mechanics Pvt. Ltd., India

Model: HO-TH-OSC

The speed of rotation can be ramped with a microcontroller

Fabrication of thin polymer films. Spin coater is used to thin film applications. Solution is dropped on top of the substrate and spin at particular RPM to obtain thin film. 9 programs can be set and duration of spin and UV drying can be varied from seconds to hours.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.sc@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 100
Research Scholar from Academic Institution 100
Project Staff from Academic Institution 100
Faculty Members from Academic Institution 100
Research Scientist from R&D Organizations 200
Industry Personnel from Industry 200
Personnel from Non - Government Organization 200

Make: Holmarc opto-mechanics Pvt. Ltd., India

Model: HO-TH-OSC

Study of phase transitions, absorption, adsorption, desorption; chemisorption, thermal decomposition and solid-gas reactions. Heat flow into or out of a sample.

  • Thermogravimetric analysis or thermal gravimetric analysis (TGA) is a method of thermal analysis in which the mass of a sample is measured over time as the temperature changes. This measurement provides information about physical phenomena, such as phase transitions, absorption, adsorption and desorption; as well as chemical phenomena including chemisorptions, thermal decomposition, and solid-gas reactions.
  • Differential Scanning Calorimetry (DSC) is a thermal analysis technique in which the heat flow into or out of a sample is measured as a function of temperature or time, while the sample is exposed to a controlled temperature program

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.tgadsc@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution TGA: 500
DSC: 1500
TGA + DSC: 1900
Research Scholar from Academic Institution TGA: 500
DSC: 1500
TGA + DSC: 1900
Project Staff from Academic Institution TGA: 500
DSC: 1500
TGA + DSC: 1900
Faculty Members from Academic Institution TGA: 500
DSC: 1500
TGA + DSC: 1900
Research Scientist from R&D Organizations TGA: 1000
DSC: 2500
TGA + DSC: 3200
Industry Personnel from Industry TGA: 1000
DSC: 2500
TGA + DSC: 3200
Personnel from Non - Government Organization TGA: 1000
DSC: 2500
TGA + DSC: 3200

Make: Decagon Devices, Inc.

Model: KD2 pro

Measures thermal conductivity, resistivity, volumetric specific heat capacity, diffusivity, individual heat transfer coefficient.

Measures thermal conductivity, resistivity of liquid samples and measure the thermal conductivity, resistivity, volumetric specific heat capacity, diffusivity, individual heat transfer coefficient of solid samples.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.tcm@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution Temperature range 10 - 50 °C : 500
Temperature range 10 - >50 °C : 1000
Research Scholar from Academic Institution Temperature range 10 - 50 °C : 500
Temperature range 10 - >50 °C : 1000
Project Staff from Academic Institution Temperature range 10 - 50 °C : 500
Temperature range 10 - >50 °C : 1000
Faculty Members from Academic Institution Temperature range 10 - 50 °C : 500
Temperature range 10 - >50 °C : 1000
Research Scientist from R&D Organizations Temperature range 10 - 50 °C : 1000
Temperature range 10 - >50 °C : 2000
Industry Personnel from Industry Temperature range 10 - 50 °C : 1000
Temperature range 10 - >50 °C : 2000
Personnel from Non - Government Organization Temperature range 10 - 50 °C : 1000
Temperature range 10 - >50 °C : 2000

Make: Specord

Model: 210 plus

Study the optical properties includes absorbance and transmittance spectra of samples

To study the optical properties includes absorbance (E.g. Photo degradation), and transmittance spectra for liquid samples. Additionally, we have thin film and DLS measuring setup for semiconductor nanomaterial covers the range from 200 to 800 nm.

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.uvvas@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 100
Research Scholar from Academic Institution 100
Project Staff from Academic Institution 100
Faculty Members from Academic Institution 100
Research Scientist from R&D Organizations 200
Industry Personnel from Industry 200
Personnel from Non - Government Organization 200

Make: BROOKFIELD

Model: DV2T

Measures viscosity, shear stress and applied force in Newton

Study the physical properties of liquid samples

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.viscometer@vit.ac.in
Phone: 0416-2202412

User Type Charges (INR) (+ applicable GST)
UG /PG Students from Academic Institution 500
Research Scholar from Academic Institution 500
Project Staff from Academic Institution 500
Faculty Members from Academic Institution 500
Research Scientist from R&D Organizations 1000
Industry Personnel from Industry 1000
Personnel from Non - Government Organization 1000

Make: Edinburgh Instruments, UK

Model: FLS1000-SS-s

  • PL Emission scan
  • 2. Lifetime Measurements in µs
Mode of Operation PL Emission scan (Single Photon Counting) Lifetime Measurement (Time-Correlated Single Photon Counting (TCSPC))
Source 450 W xenon lamp (Xe2) µF1 - 5 W Microsecond Flashlamp
Spectral range 250 nm - 820 nm 5µs to 200s

Useful for researchers/ academicians/ industries working in the areas of photophysics, photochemistry, biophysics, biochemistry, material and life sciences. Some of the key applications are as following:

  • Optoelectronic properties of an inorganic and organic LED device
  • Photoluminescence of Lanthanide-based Optical Probes
  • Kinetics of Persistent Luminescence Phosphors
  • Energy transfer studies using time-resolved emission spectroscopy
  • Photophysical Characterisation of Perovskite Quantum Dots
  • Determination of Chromaticity Coordinates, and Bandgaps of III-V LEDs
  • Excitation-Emission Spectroscopy of Single-Wall Carbon Nanotubes
  • Photoluminescence of Organic Solar Cells
  • PL emission from DC and AC electroluminescence panels and flexible light emitting devices.
  • Luminescence quenching studies
  • Energy transfer kinetics (intermolecular FRET)
  • Research of Molecular Processes and Mechanisms (Photo-sensitizers)

Industrial applications

  • Anti-countering solutions based on luminescent probes
  • Lighting and display industries working LCD, LED
  • Industries related to pharmaceuticals, healthcare, food and beverages
  • Industries related to dyes and pigments

Room No. 027,
Ground Floor, Technology Tower Centre for Nanotechnology Research,
Vellore Institute of Technology, Vellore – 632 014.

Dr. George Jacob,
Assistant Professor Senior,
Centre for Nanotechnology Research.
Email: cnr.pl@vit.ac.in

Internal Users

EQUIPMENT_NAME UG /PG Students(in INR) Research Scholar (in INR) Faculty Members/ Project Staff (in INR)
Photoluminescence Spectrometer - Emission scan only 200 200 200
Photoluminescence Spectrometer - Time resolved studies (Lifetime Measurements in µs) only 400 400 400
Photoluminescence Spectrometer - Emission scan and Lifetime Measurements in µs - Together 500 500 500

External Users

EQUIPMENT_NAME UG /PG Students from Academic Institution (in INR) Research Scholar from Academic Institution (in INR) Project Staff from Academic Institution (in INR) Faculty Members from Academic Institution (in INR) Research Scientist from R&D Organizations (in INR) Industry Personnel from Industry (in INR) Personnel from Non - Government Organization (in INR)
Photoluminescence Spectrometer - Emission scan only 500 500 500 500 750 750 750
Photoluminescence Spectrometer - Time resolved studies (Lifetime Measurements in µs) only 1000 1000 1000 1000 1500 1500 1500
Photoluminescence Spectrometer - Emission scan and Lifetime Measurements in µs - Together 1400 1400 1400 1400 2000 2000 2000

Make: Bruker Dektak XT

Model: Bruker Dektak XT

Thickness measurement of thin film and thick films up to mm, Step height measurement, surface topography and waviness profile
Solar cells, Thin films, Sensors, Optics, Etching, Photoresist thickness

Room No.: 027
Ground Floor
Technology Tower
Nanotechnology Lab
Centre for Nanotechnology Research

Prof. George Jacob,
Assistant Professor (Sr.),
Centre for Nanotechnology Research,
VIT, Vellore, TN-632014.
Email: cnr.sp@vit.ac.in
Phone: 0416-2202412

Internal Users

EQUIPMENT_NAME UG /PG Students(in INR) Research Scholar (in INR) Faculty Members/ Project Staff (in INR)
Surface Profiliometer 200 200 200

External Users

EQUIPMENT_NAME UG /PG Students from Academic Institution (in INR) Research Scholar from Academic Institution (in INR) Project Staff from Academic Institution (in INR) Faculty Members from Academic Institution (in INR) esearch Scientist from R&D Organizations (in INR) ndustry Personnel from Industry (in INR) ersonnel from Non - Government Organization (in INR)
Surface Profiliometer 500 500 500 500 1000 1000 1000