Make: Perkin Elmer

Model: AANALYST 400

  • Spectrometer: True double-beam echelle optical system.
  • Detector: High-efficiency, segmented solid-state detector.
  • Absorbance range : 189-900 nm.
  • Spectral resolution: 0.12 nm at 200 nm.
  • HGA 900 Graphite Furnace and Flame method
  • Multi element analysis capability. (Ag, Al, Au, Cd, Cr, Cu, Fe, Pb, Se, Ti, Zn)
AAS Spectroscopy is commonly used to measure the concentration of metals and metalloids in environmental samples, biological samples, food technology, agriculture and Nanomaterials etc.,

Room No. 415
Pearl Research Park
Centre for Nanobiotechnology.

Dr. P. Mrudula, Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.aas@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institution 1000/element + 300/(each add element)
2 Research Scholar from Academic Institution 1000/element + 300/(each add element)
3 Project Staff from Academic Institution 1000/element + 300/(each add element)
4 Faculty Members from Academic Institution 1000/element + 300/(each add element)
5 Research Scientist from R&D Organizations 1500/element + 300/(each add element)
6 Industry Personnel from Industry 1500/element + 300/(each add element)
7 Personnel from Non - Government Organization 1500/element + 300/(each add element)

Make: Jasco

Model: FT/IR-6800

  • Measuring Range 7800-350 cm-1
  • Step scan and high resolution.
  • Max resolution: 0.07cm-1.
  • Absorbance and Transmittance information.
FTIR to analyse the composition and properties of polymers, coatings, and other materials, identification and characterization of chemical compounds, and various applications including Environmental sample analysis, Materials science, Medicine and pharmaceuticals, Food and beverage analysis.

Room No. 417
Pearl Research Park
Centre for Nanobiotechnology.

Dr. John Thomas
Associate Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.ftir@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institution 500
2 Research Scholar from Academic Institution 500
3 Project Staff from Academic Institution 500
4 Faculty Members from Academic Institution 500
5 Research Scientist from R&D Organizations 1000
6 Industry Personnel from Industry 1000
7 Personnel from Non - Government Organization 1000

Make: Kyowa Interface Science

Model: DMs-401

Measuring range: contact angle: 0.1 to 180°, surface/interfacial tension: 0.1 to 100mN/m
Resolution: contact angle: 0.1°, surface/interfacial tension: 0.1mN/m
Accuracy: contact angle: 0.2°, surface/interfacial tension: 0.2mN/m
Camera system: USB2.0 CMOS camera: 60fps at 640x480 pixels
Optical system: Focus: manual focus with 3-step zoom
field of view: 5.3x4.0mm, 9.6x7.2mm, 13.6x10.2mm ±6%
Measuring methods : contact angle: sessile drop (static and dynamic)
surface/interfacial tension: pendant drop (static and dynamic)
  • Automatic recognition of droplet deposition
  • Live image display and droplet volume monitoring
  • Fine adjustable stage in z-axis for gentle deposition of droplets without distortion
  • Adjustable level of the body and stage
  • Droplet calibration standard for standard view, bearing one full circle for calibration and three droplet silhouettes of 5°, 60°, and 108° for periodic inspection of measurement accuracy
This technique is used to measure the hydrophobicity or hydrophilicity of a surface through the value of the contact angle.
  • Wettability of different surfaces including metals, ceramics, plastic, glass, Nanomaterials etc.,

Room No. 415
Pearl Research Park
Centre for Nanobiotechnology.

Dr. P. Mrudula
Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.gonio@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institution 500
2 Research Scholar from Academic Institution 500
3 Project Staff from Academic Institution 500
4 Faculty Members from Academic Institution 500
5 Research Scientist from R&D Organizations 750
6 Industry Personnel from Industry 750
7 Personnel from Non - Government Organization 750

Make: Anton Paar

Model: Cora 5001 DUAL

  • Dual Wavelength
  • Excitation Wavelength - 532nm and 785nm
  • Spectral Range - 200 cm-1 to 3500 cm-1 for 532 nm, 100 cm-1 to 2300 cm-1 for 785 nm
  • Resolution - 9 cm-1 to 12 cm-1 for 532 nm; 6 cm-1 to 9 cm-1 for 785 nm
  • Laser Power-50 mW for 532 nm; 0 mW to 450 mW for 785 nm
  • Detector array-2048 px CCD for 532 nm and 785 nm
Raman spectroscopy is widely used to identify unknown substances, verify samples in quality assurance, analyze the chemical composition of samples or monitor their changes.

Room No. 417
Pearl Research Park
Centre for Nanobiotechnology.

Dr. John Thomas
Associate Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.raman@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institution 500
2 Research Scholar from Academic Institution 500
3 Project Staff from Academic Institution 500
4 Faculty Members from Academic Institution 500
5 Research Scientist from R&D Organizations 1000
6 Industry Personnel from Industry 1000
7 Personnel from Non - Government Organization 1000

Make: Horiba Scientific

Model: SZ-100

  • Particles size measurements at both 90° and 173°
  • Zeta Potential
  • Measurement Range : Particle diameter: 0.3 nm - 5.0 micrometer
  • Measurement Accuracy: NIST traceable polystyrene latex particle standard (100 nm measurement accuracy = + / - 2%)
  • Proteins/complexes/DNA
  • Polymer Latexes
  • Pharmaceutical Preparations
  • Oil/Water and Water/Oil Emulsions
  • Paints and Pigments
  • Inks and Toners
  • Cosmetic Formulations

Room No. 417
Pearl Research Park
Centre for Nanobiotechnology.

Dr. John Thomas
Associate Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.dls@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institution 500
2 Research Scholar from Academic Institution 500
3 Project Staff from Academic Institution 500
4 Faculty Members from Academic Institution 500
5 Research Scientist from R&D Organizations 1000
6 Industry Personnel from Industry 1000
7 Personnel from Non - Government Organization 1000

Make: Shimadzu

Model: TOC-L CPH E200

  • TOC-LCPH High Sensitivity Model
  • Capable of TC, IC, TOC (= TC-IC)
  • Measurement range from 4 µg/L to 30,000 mg/L
  • Reliable sample injection system
  • Suitable for Aqueous samples

TOC analyzers is used in various fields such as

  • Drinking Water & Wastewater Treatment
  • Pharmaceutical Industry and Industrial Process Water
  • Aquaculture Monitoring & Environmental Monitoring
  • Surface Water Management
  • Process Water, Pure Water & Wastewater in Chemical Manufacturing
  • Pure Water, Ultra-Pure Water in Semiconductor
  • Process Water, Pure Water in Agricultural Production
  • Surface Water and Ground Water Analysis

Room No. 415
Pearl Research Park
Centre for Nanobiotechnology

Dr. P. Mrudula,
Professor
Centre for Nanobiotechnology
VIT, Vellore-632014
Email: cnbt.toc@vit.ac.in
Phone: 0416 2204214

S. No Category Charges (INR) (+ Applicable GST)
1 UG /PG Students from Academic Institutions 750
2 Research Scholar from Academic Institutions 750
3 Project Staff from Academic Institutions 750
4 Faculty Members from Academic Institutions 750
5 Research Scientist from R&D Organizations 1000
6 Industry Personnel from Industry 1000
7 Personnel from Non - Government Organizations 1000

Make:

Model: