Make: Atomic Force Microscopy (AFM)
Model: Park Systems NX10, Atomic Force Microscope
- Specification
- Superior Imaging Performance.
- True Non-Contact Mode: Maintains high resolution and prevents tip wear/sample damage by avoiding direct contact during imaging.
- Low Noise Z-Detector: Features a detector noise floor of 0.02 nm, delivering high-accuracy topography without the need for frequent calibration.
- Flat XY Scanning: The flexure-guided scanner provides less than 1 nm runout over a 100-micron scan, ensuring negligible background curvature.
- Capabilities
-
Capabilities
- The Park NX10 is a high-performance, research-grade Atomic Force Microscope (AFM) designed for accurate, user-friendly, and versatile nanoscale imaging and measurement.
- Key capabilities include flat, orthogonal scanning with minimal bow, low-noise detectors, and specialized True Non-Contact mode.
- Preserves tip sharpness for superior data, especially on soft or delicate samples.
-
2D Flexure-Guided Scanner with 100 μm x 100 μm Scan Range
- The XY scanner consists of symmetrical 2-dimensional flexure and high-force piezoelectric stacks.
- Provides high orthogonal movement with minimal out-of-plane motion.
- Ensures high responsiveness for precise nanoscale scanning.
- Compact and rigid structure enables low noise and high-speed servo response.
-
High Speed Z Scanner with 15 μm Scan Range
- Driven by a high-force piezoelectric stack and guided by a flexure structure.
- High resonant frequency of more than 9 kHz (typically 10.5 kHz).
- Ultra-fast Z-servo speed of more than 48 mm/sec tip velocity.
- Z scan range extendable from 15 μm to 30 μm with optional long-range scanner.
-
Low Noise XYZ Position Sensors
- Industry-leading low noise Z detector replaces applied Z voltage as the topography signal.
- Low noise XY closed-loop scan minimizes forward and backward scan gap to less than 0.15% of the scan range.
-
AFM Software
- Dedicated system control and data acquisition software.
- Real-time feedback parameter adjustment.
- Script-level control through external programs (optional).
- AFM data analysis software (NXI).
- Applications
-
- The Z stage and focus stage engage the cantilever with the sample surface while maintaining a clear field of vision for the user.
- The motorized, software-controlled focus stage provides high precision.
- Suitable for transparent samples and liquid cell applications.
- Charges
| S. No. | Experiment Details | UG / PG Students (INR) | Research Scholar (INR) | Project Staff (INR) | Faculty Members (INR) | Research Scientist (INR) | Industry Personnel (INR) |
|---|---|---|---|---|---|---|---|
| 1 | Non-Contact Mode (Solid/Thin film) | 2500 | 2500 | 2500 | 2500 | 4000 | 4000 |
* Charges are per sample in INR (+ applicable GST)
- Location
Room No.: 243 PRP ‘A’ Block
VIT’s Centre for Advanced Research Facility and Testing (VCART)
Vellore Institute of Technology (VIT), Vellore.
- Contact
Dr. Annamalai Senthil Kumar, CChem., FRSC
Coordinator, VIT’s Centre for Advanced Research Facility and Testing (VCART)
Vellore Institute of Technology, Vellore-632014, Tamil Nadu
Email: vcart@vit.ac.in
Coordinator, VIT’s Centre for Advanced Research Facility and Testing (VCART)
Vellore Institute of Technology, Vellore-632014, Tamil Nadu
Email: vcart@vit.ac.in